Independent guide, not a government website. Water Operator Hub is not affiliated with any state agency or certification board. Rules and fees change; always confirm with your state's program (we link the official page on every state guide).

Wastewater math: F/M ratio, SVI & sludge age

Activated sludge process-control questions use a few formulas. Most of them feed the pounds formula into a ratio. Once you can turn mg/L and MG into pounds, these become straightforward.

In plain English

Pounds = Volume (MG) × Concentration (mg/L) × 8.34 F/M = BOD (lbs/day) ÷ MLVSS under aeration (lbs) SVI (mL/g) = 30-min settled volume (mL/L) × 1,000 ÷ MLSS (mg/L) Sludge age (days) = Solids under aeration (lbs) ÷ Solids added (lbs/day) MCRT (days) = (Aeration TSS lbs + Clarifier TSS lbs) ÷ (WAS lbs/day + Effluent TSS lbs/day)

Note: some sheets write F/M with "CBOD applied" (Ohio EPA) or "influent CBOD" (Florida DEP). Use the BOD or CBOD value your question gives.

Worked example 1: F/M ratio

Flow is 2.0 MGD with 150 mg/L BOD entering aeration. The aeration tanks hold 0.75 MG with an MLVSS of 2,500 mg/L. What is the F/M?

  1. Food: 2.0 × 150 × 8.34 = 2,502 lbs/day BOD
  2. Microorganisms: 0.75 × 2,500 × 8.34 = 15,637.5 lbs MLVSS
  3. F/M: 2,502 ÷ 15,637.5 = 0.16

Worked example 2: SVI

After 30 minutes, the settleometer shows 300 mL/L. MLSS is 3,000 mg/L. What is the SVI?

  1. 300 × 1,000 ÷ 3,000 = 100 mL/g

Worked example 3: sludge age and MCRT

The aeration tanks (0.75 MG) run at 3,000 mg/L MLSS. Primary effluent TSS is 120 mg/L at 2.0 MGD. The clarifier holds 2,000 lbs of solids. WAS is 0.04 MGD at 8,000 mg/L, and effluent TSS is 10 mg/L. Find the sludge age and the MCRT.

  1. Solids under aeration: 0.75 × 3,000 × 8.34 = 18,765 lbs
  2. Solids added: 2.0 × 120 × 8.34 = 2,001.6 lbs/day
  3. Sludge age: 18,765 ÷ 2,001.6 = 9.375 → about 9.4 days
  4. WAS solids: 0.04 × 8,000 × 8.34 = 2,668.8 lbs/day; effluent solids: 2.0 × 10 × 8.34 = 166.8 lbs/day
  5. MCRT: (18,765 + 2,000) ÷ (2,668.8 + 166.8) = 20,765 ÷ 2,835.6 = 7.32 → about 7.3 days

Practice problems

1. Settled volume is 250 mL/L and MLSS is 2,200 mg/L. SVI?

250 × 1,000 ÷ 2,200 = 113.6 → about 114 mL/g

2. 1.2 MGD at 180 mg/L BOD enters a 0.5 MG aeration basin with MLVSS of 2,000 mg/L. F/M?

Food: 1.2 × 180 × 8.34 = 1,801.4 lbs/day. MLVSS: 0.5 × 2,000 × 8.34 = 8,340 lbs. 1,801.4 ÷ 8,340 = 0.216 → about 0.22

3. A 1.0 MG aeration tank at 2,800 mg/L MLSS receives 1.5 MGD of primary effluent with 100 mg/L TSS. Sludge age?

Under aeration: 1.0 × 2,800 × 8.34 = 23,352 lbs. Added: 1.5 × 100 × 8.34 = 1,251 lbs/day. 23,352 ÷ 1,251 = 18.67 → about 18.7 days

Formula sources

The formulas on this page match these published exam formula sheets: NC DEQ, Basic Water Treatment Math Formulas (surface & well); Ohio EPA, Applied Wastewater Math Formula Sheet; Florida DEP, Wastewater Treatment Formulas/Conversion Table; WPI (formerly ABC) formula/conversion tables. Use the sheet your own exam provides on test day; layouts and rounding vary. Every number in the examples was recalculated with a script before publishing. These are study examples, not operating guidance.